WINDOWS TO THE BRAIN
Published Online: 1 October 2010

Optical Imaging: A New Window to the Adult Brain

Publication: The Journal of Neuropsychiatry and Clinical Neurosciences
N oninvasive optical imaging is an emerging method of functional neuroimaging that has major advantages that make it particularly suited to both basic and clinical neuroscience research as well as to clinical practice. 27 It has great promise for contributing to neuropsychiatry. 2 The required equipment is compact and portable, it is relatively easy to use, and the method is relatively tolerant of subject movement. Studies can be performed in almost any location including at the bedside and in natural settings. Patients who are not good candidates for more traditional functional imaging methods (e.g., functional MRI [fMRI] and positron emission tomography [PET]) often do well with optical imaging, as it does not require absolute stillness or confinement and has no associated loud noises. It is also safe to use in the presence of metal (e.g., plates, pins, pacemakers), an important consideration for some populations of interest. It has much faster time resolution than most other functional imaging techniques and can easily provide repeated within-subject measures. Other major advantages are low cost and high safety. Like surface electroencephalography (EEG), optical imaging captures activation-related changes only from the cerebral cortex. Historically, the major disadvantages of optical imaging have been its lower spatial resolution and smaller regions of coverage, areas of major improvement over the last decade. Use of optical imaging for monitoring of cerebral state in high-risk situations (e.g., neurosurgery, intensive care unit), while an important clinical application, is outside the scope of this review. 810
The concept that the functional state of tissue influences its optical properties in observable ways is well accepted. Familiar medical examples include hypoxia-induced cyanosis and anemia-related pallor. Both result from changes in the concentration of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR). Hemoglobin (Hb) is a chromophore, a chemical group that absorbs light at a specific frequency, thus imparting coloration. Most noninvasive optical neuroimaging approaches presently used in clinical practice and human research are based on using some version of near-infrared spectroscopy (NIRS) to measure intrinsic activation-related changes in the concentrations of oxyhemoglobin and deoxyhemoglobin. Thus, similar to fMRI, optical neuroimaging measures the hemodynamic response to brain activation. Unlike fMRI, which is based on detecting activation-related changes in HbR, NIRS can monitor localized changes in cerebral blood volume and both HbO2 and HbR.
The initial demonstration of NIRS-based noninvasive monitoring of cerebral oxygenation state utilized transmission of light through the tissue of interest (transillumination). 11 While very useful for thinner structures (e.g., finger pulse oximetry), this approach is not well suited to noninvasive monitoring of the adult brain due to the size of the adult head and the thickness of overlying structures (e.g., scalp, skull, dura, CSF). It was not until the development of techniques based on detection of light emerging from the surface near the light source that NIRS began to be more widely utilized for human research. 12 The interaction between light and tissue depends upon scattering and absorption at the particular wavelength. 27 Scattering decreases with increasing wavelength. Compared to visible light, light in the near-infrared range easily penetrates into tissue. Unlike X-ray photons, which travel in a straight line through soft tissues (due to their higher energy), near-infrared photons will change direction multiple times ( Figure 1 ). Although comparatively less in the near-infrared range, scatter limits penetration depth and spatial resolution. Absorption in the near-infrared range is primarily due to the presence of endogenous chromophores such as water, hemoglobin, bilirubin, and cytochrome ( Figure 2 ). Tissue penetration is best at wavelengths between ∼700–900 nm. (Depth sensitivity is limited by hemoglobin absorption below this range and water absorption above it.) In this range, sometimes called the “biological optical window” or the “medical spectral window,” light can penetrate into tissue as much as several centimeters and still return to detectors at the surface. The separation between the source and detector is an essential factor in determining depth sensitivity, as photons reaching a detector farther from the source are more likely to have penetrated more deeply ( Figure 1 ). 13 Thus, signals from closely spaced source-detector pairs will be more sensitive to superficial tissues (e.g., scalp). This can be used to mathematically compensate for the effects of signal from superficial tissues on signals acquired from more widely spaced source-detector pairs.
Figure 1. Light in the near-infrared range scatters as it penetrates tissue (left). The photons change direction many times as they travel from the light source (yellow) to the light detector (green). On average, they follow a generally curved (“banana shaped”) path, so photons reaching a detector farther from the source are more likely to have penetrated more deeply. Thus, the spacing of sources and detectors determines the depth sensitivity of the measurements (right). In general, the depth sampled is ∼1/3 the distance between source and detector.
Figure 2. In the near-infrared range the major light-absorbing chromophores in tissue are water (gold), hemoglobin (oxyhemoglobin, pink; deoxyhemoglobin, blue), and cytochrome oxidase (green). Light penetrates tissue most deeply at wavelengths between ∼700–900 nm (gray band). Measurements are made at several wavelengths in order to be differentially sensitive to changes in oxyhemoglobin and deoxyhemoglobin. Measurement at an isobestic point (arrow), a wavelength equally sensitive to both, is sensitive to changes in total hemoglobin concentration.
Optical imaging requires the use of devices (known as optodes) for coupling light between an optoelectronic component (e.g., light source, photodetector) and a surface (e.g., skin, scalp). 27 By utilizing more than one wavelength of light, measurements can be made that are differentially sensitive to changes in oxyhemoglobin and deoxyhemoglobin ( Figure 2 ). Some wavelengths are equally sensitive to both (isobestic points). At an isobestic point, changes in total hemoglobin concentration (HbT) can be measured directly. Although there are methods for measuring absolute concentrations, most optical imaging measures change relative to initial conditions ( Figure 3 ).
Cover and Figure 3. Optical imaging is based on task-related brain activation-induced focal changes in the concentration of oxyhemoglobin (pink) and deoxyhemoglobin (blue). Illustrated here are data from two regions of interest (three detectors each, approximate areas sampled indicated by yellow circles on cover) averaged across eight subjects performing simple mental arithmetic (adapted from Pfurtscheller et al. 1 ). Oxyhemoglobin was focally increased in the dorsolateral prefrontal cortex (pink, solid line) and decreased in the anterior prefrontal cortex (pink, dashed line). As noted by the authors, these results are consistent with findings from EEG and fMRI studies, and may be indicative of focal activation with surround deactivation.
There are three major methods of noninvasive optical imaging. 27 The simplest approach is the original continuous wave method in which light sources provide a signal of constant amplitude and detectors measure light amplitude attenuation. Under these conditions, it is not possible to directly measure the scattering properties of tissue which cause photons to travel along different paths (and have different pathlengths) between the source and detector ( Figure 1 ). Assumption-based modeling and computer simulations are required to estimate these effects. Advantages of the continuous wave method include low cost; high safety (it can be done with light emitting diodes [LEDs]); and smaller, very portable equipment that is easily used in clinical settings and natural environments. Major disadvantages are limited spatial resolution (particularly in the more portable systems) and provision of relative rather than absolute measures of concentration change. The more complex time-resolved and frequency-domain approaches to optical imaging both provide better sensitivity, but require use of laser light sources, which increase cost and introduce potential safety issues. For time-resolved optical imaging, a pulsed laser is used as the light source, and the time it takes photons to arrive at the detector is measured (time of flight). 14 One benefit of this approach is that early arriving photons (short time of flight) have penetrated less deeply into tissue (shorter pathlength). Thus, the temporal distribution of photons can be used to resolve depth. For frequency-domain optical imaging, the light source is modulated and the phase delay (phase shift) of light at the detector(s) provides a measure of time of flight. 15 Greater phase delay indicates photons that have traveled more deeply (longer pathlength). Optimizing analysis of these types of data in order to improve depth sensitivity and quantitation is an area of very active research.
The two methods for analyzing noninvasive optical neuroimaging data in humans are optical topography and diffuse optical tomography (DOT). Optical topography is done with a sparse array ( Figure 4 ). Pairs of light-emitting and light-detecting optodes are separated by 2–4 cm, providing lower (generally >5 mm) spatial resolution. Point measurements are interpolated into a 2D topographic activation map that can be roughly superimposed onto the area of brain underlying the probe array. Diffuse optical tomography is generally done with a denser array ( Figure 4 ). 1618 Dense arrays provide source-detector pairs with multiple separations. As noted in Figure 1, pairs that are close together will be more sensitive to superficial tissues (e.g., scalp, skull), whereas pairs with a greater separation will be more sensitive to deeper tissues (e.g., cortex). In diffuse optical tomography, overlapping information from multiple detector pairs can be combined in the form of a model-based 3D image reconstruction. Reconstructing data can improve depth sensitivity and decrease physiological noise. Recent studies have demonstrated the feasibility of much higher resolution mapping of limited areas of the cortex using tomographic reconstruction approaches. 16, 18, 19
Figure 4. Both optical topography and diffuse optical tomography are based on data collected from an array of sources and detectors. The major difference is in the analysis method utilized. Optical topography is most commonly performed using a sparse array (left side of figure) of sources (yellow) and detectors (green). These are generally separated by 2–4 cm. Spectral measures are interpolated to provide a low-resolution activation map. This can be roughly superimposed (generally using skull landmarks) onto a 3D brain MRI. Diffuse optical tomography is performed using a dense array (right side of figure). Data from multiple source-detector pairs with a range of separations provide overlapping measurement from a limited area. These are used for tomographic image reconstruction utilizing a 3D model that then can be superimposed onto an MRI.
As described in recent review articles, optical neuroimaging has been utilized to study motor, sensory, and cognitive task-related activations in multiple populations including the very young and elderly and individuals with psychiatric disorders. 24 Recent studies illustrate the application of optical neuroimaging to processes and tasks that previously were not amenable to functional imaging. Monitoring during performance in more naturalistic situations allows exploration of complex cognitive functions. For example, a study that acquired repeated measures while the subjects performed a simulated naval air warfare management task that varied on task load, task difficulty, and requirement for divided attention found positive correlations between level of activations and level of performance. 20 Similarly, a study that acquired repeated measures while the subject was playing a game of Japanese chess ( shogi ) was able to correlate the cognitive demand level of the game stage with location and extent of activation. 21 Another that acquired repeated measures during a conversational task supports the potential for studying social interactions in a natural setting. 22 Other studies comparing task-related activation during actually performing a motor task versus some form of pretence (e.g., peeling an apple versus making similar hand motions, physically executing a movement versus mentally imagining performing it) have found that the activations differ, underscoring the importance of a functional imaging technique that allows subjects to move freely. 23, 24
Optical neuroimaging also has the potential to improve clinical management in a variety of ways. For example, it may be useful for early diagnosis of some conditions. A recent study evaluated the potential of optical neuroimaging to inform diagnosis of Alzheimer’s disease based on the known early onset of visuospatial deficits in this population. 25 Performance was similar between groups on a simple line orientation naming task, but patients with mild-moderate dementia likely due to Alzheimer’s disease had much less activation in parietal cortex compared to age-matched healthy individuals. As noted by the authors, studies of individuals with mild cognitive impairment are required to fully evaluate the potential diagnostic utility of this approach. Initial studies in which optical neuroimaging has been combined with treatment indicate the potential of this technique to monitor treatment response and provide insight into the processes underlying clinical efficacy. 26, 27
Similar to other neuroimaging methods, individual differences in physiology and anatomy are a potentially important source of variability in optical neuroimaging. Study participants can differ considerably in the proportion of hemoglobin in the arterial and venous compartments, as well as in total hemoglobin concentration. 7 Thickness and composition of the superficial layers, especially the skull and CSF, also vary across individuals. In some studies, addition of structural imaging (e.g., MRI, CT) has been used to improve localization by using models of light propagation that are based on the individual subject’s anatomy.
Optical neuroimaging is a relatively new addition to the field of functional neuroimaging, and there is little standardization as of yet. There is a growing effort within the optical imaging community to develop a more systematic framework for experimental design and data analysis. 5, 6, 28 One area of particular concern is minimizing factors that degrade the signal of interest. Inadequate shielding and/or poor coupling between optode and skin can allow ambient light to reach detectors. This has been addressed in multiple ways including decreasing ambient light (e.g., dim room light, covering sensor array with dark or opaque material), filtering, and differential detection. Movement of sources and detectors relative to the scalp can also cause significant changes in the coupling of light into and out of the head. Hair exacerbates this problem since it is highly absorbing (due to its melanin content) and can interfere with probe contact, causing fluctuations in light delivery and detection during movement. Thus, in addition to spring-loading of optodes to improve contact, secure anchoring of the probe array is essential. Elasticized bandages are commonly used to hold smaller arrays in place. Caps and helmets have been developed to accommodate larger arrays and tasks requiring more movement. Optimizing the probe design to match the demands of the desired task is recommended. Identification of motion artifacts can be done by visual inspection of data, as they are generally very large compared to the signal. Statistical methods for motion detection/correction (e.g., outlier detection, principal component analysis) have also been developed. Physiological noise (e.g., respiration, heart rate, etc.) will also be present. Filtering, signal averaging, gating, and comparing signals from near and distant detector pairs have all been used to decrease its impact on signal. 5, 6, 28
In summary, noninvasive optical imaging is an exciting new approach to functional neuroimaging with many advantages for use in psychiatric research. These include the ability to perform studies in a wide range of settings and in patient populations unable to tolerate confinement or loud noises. There is clear potential for applications to clinical care. In addition, there are optical imaging techniques in much earlier stages of development that hold the potential of providing entirely new types of information. One approach may allow optical imaging of brain activation directly by measurement of activation-induced intrinsic light scattering changes. 15, 29 Another is development of fluorescent compounds that may have use as optical contrast agents. 30, 31 Thus, optical imaging may provide a future tool for both assessment and monitoring treatment response in psychiatric illness.

Footnote

Drs. Taber and Hurley are affiliated with the Veterans Affairs Mid-Atlantic Mental Illness Research, Education, and Clinical Center, and the Research and Education Service Line at the W.G. Hefner Veterans Affairs Medical Center in Salisbury, North Carolina; Dr. Taber is affiliated with the Division of Biomedical Sciences at the Virginia College of Osteopathic Medicine in Blacksburg, Virginia, and the Department of Physical Medicine and Rehabilitation at Baylor College of Medicine in Houston, Texas. Dr. Hillman is affiliated with the Department of Biomedical Engineering and Radiology at Columbia University in New York. Dr. Hurley is affiliated with the Departments of Psychiatry and Radiology at Wake Forest University School of Medicine in Winston-Salem, North Carolina, and the Menninger Department of Psychiatry and Behavioral Sciences at Baylor College of Medicine in Houston. Address correspondence to Dr. Robin Hurley, Hefner VA Medical Center, 1601 Brenner Ave., Salisbury, NC 28144; [email protected] (e-mail).
Copyright © 2010 American Psychiatric Publishing, Inc.

References

1.
Pfurtscheller G, Bauernfeind G, Wriessnegger SC, et al: Focal frontal (de)oxyhemoglobin responses to simple arithmetic. Int J Psychophysiol 2010; 76:186–192
2.
Arenth PM, Ricker JH, Schultheis MT: Applications of functional near-infrared spectroscopy (fNIRS) to neurorehabilitation of cognitive disabilities. Clin Neuropsychol 2007; 21:38–57
3.
Obrig H, Villringer A: Beyond the visible-imaging the human brain with light. J Cereb Blood Flow Metab 2003; 23:1–18
4.
Irani F, Platek SM, Bunce S, et al: Functional near infrared spectroscopy (fNIRS): an emerging neuroimaging technology with important applications for the study of brain disorders. Clin Neuropsychol 2007; 21:9–37
5.
Hillman EM: Optical brain imaging in vivo: techniques and applications from animal to man. J Biomed Opt 2007; 12:051402
6.
Huppert TJ, Diamond SG, Franceschini MA, et al: HomER: a review of time-series analysis methods for near-infrared spectroscopy of the brain. Appl Opt 2009; 48:D280–D298
7.
Murkin MJ, Arango, M: Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth 2009; 103:i3–13
8.
Toet MC, Lemmers PMA: Brain monitoring in neonates. Early Hum Dev 2009; 85:77–84
9.
Giacomini M, Bolzon M: NIRS: a useful light in a dark world? Minerva Anestesiol 2010 Jun 28. [Epub ahead of print]
10.
Robertson CS, Zager EL, Narayan RK, et al: Clinical evaluation of a portable near-infrared device for detection of traumatic intracranial hematomas. J Neurotrauma 2010; 27:1597–1604
11.
Jobiss F: Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977; 198:1264–1267
12.
Villringer A, Chance, B: Non-invasive optical spectroscopy and imaging of human brain function. Trends Neurosci 1997; 20:435–442
13.
Mansouri C, L'huillier JP, Kashou NH, et al: Depth sensitivity analysis of functional near-infrared spectroscopy measurement using three-dimensional Monte Carlo modelling-based magnetic resonance imaging. Lasers Med Sci 2010; 25:431–438
14.
Wabnitz H, Moeller M, Liebert A, et al: Time-resolved near-infrared spectroscopy and imaging of the adult human brain. Adv Exp Med Biol 2010; 662:143–148
15.
Gratton G, Fabiani M: Fast optical imaging of human brain function. Front Hum Neurosci 2010; 4:52
16.
Koch SP, Habermehl C, Mehnert J, et al: High-resolution optical functional mapping of the human somatosensory cortex. Front Neuroenergetics 2010; 2:12
17.
Gregg NM, White BR, Zeff BW, et al: Brain specificity of diffuse optical imaging: improvements from superficial signal regression and tomography. Front Neuroenergetics 2010; 2:14
18.
White BR, Culver JP: Phase-encoded retinotopy as an evaluation of diffuse optical neuroimaging. Neuroimage 2010; 49:568–577
19.
White BR, Snyder AZ, Cohen AL, et al: Mapping the human brain at rest with diffuse optical tomography. Conf Proc IEEE Eng Med Biol Soc 2009; 2009:4070–4072
20.
Izzetoglu M, Bunce SC, Izzetoglu K, et al: Functional brain imaging using near-infrared technology. IEEE Eng Med Biol Mag 2007; 26:38–46
21.
Ogata K, Honda N: Study of change in brain activity due to blood flow while playing Shogi (Japanese chess). Electromyogr Clin Neurophysiol 2010; 50:137–148
22.
Suda M, Takei Y, Aoyama Y, et al: Frontopolar activation during face-to-face conversation: an in situ study using near-infrared spectroscopy. Neuropsychologia 2010; 48:441–447
23.
Okamoto M, Dan H, Shimizu K, et al: Multimodal assessment of cortical activation during apple peeling by NIRS and fMRI. Neuroimage 2004; 21:1275–1288
24.
Amemiya K, Ishizu T, Ayabe T, et al: Effects of motor imagery on intermanual transfer: a near-infrared spectroscopy and behavioral study. Brain Res 2010; 1343:93–103
25.
Zeller JB, Herrmann MJ, Ehlis AC, et al: Altered parietal brain oxygenation in Alzheimer’s disease as assessed with near-infrared spectroscopy. Am J Geriatr Psychiatry 2010; 18:433–441
26.
Aoyama Y, Hanaoka N, Kameyama M, et al: Stimulus intensity dependence of cerebral blood volume changes in left frontal lobe by low-frequency rTMS to fight frontal lobe: a near-infrared spectroscopy study. Neurosci Res 2009; 63:47–51
27.
Ohtani T, Matsuo K, Kasai K, et al: Hemodynamic responses of eye movement desensitization and reprocessing in posttraumatic stress disorder. Neurosci Res 2009; 65:375–383
28.
Orihuela-Espina F, Leff DR, James DR, et al: Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation. Phys Med Biol 2010; 55:3701–3724
29.
Sable JJ, Rector DM, Gratton G: Optical neurophysiology based on animal models. IEEE Eng Med Biol Mag 2007; 26:17–24
30.
Liebert A, Wabnitz H, Obrig H, et al: Non-invasive detection of fluorescence from exogenous chromophores in the adult human brain. Neuroimage 2006; 31:600–608
31.
Steinbrink J, Liebert A, Wabnitz H, et al: Towards noninvasive molecular fluorescence imaging of the human brain. Neurodegener Dis 2008; 5:296–303

Information & Authors

Information

Published In

Go to The Journal of Neuropsychiatry and Clinical Neurosciences
Go to The Journal of Neuropsychiatry and Clinical Neurosciences
The Journal of Neuropsychiatry and Clinical Neurosciences
Pages: iv

History

Published online: 1 October 2010
Published in print: Fall, 2010

Authors

Details

Katherine H. Taber, Ph.D.
Elizabeth M. C. Hillman, Ph.D.

Metrics & Citations

Metrics

Citations

Export Citations

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

For more information or tips please see 'Downloading to a citation manager' in the Help menu.

Format
Citation style
Style
Copy to clipboard

View Options

View options

PDF/EPUB

View PDF/EPUB

Get Access

Login options

Already a subscriber? Access your subscription through your login credentials or your institution for full access to this article.

Personal login Institutional Login Open Athens login
Purchase Options

Purchase this article to access the full text.

PPV Articles - Journal of Neuropsychiatry and Clinical Neurosciences

PPV Articles - Journal of Neuropsychiatry and Clinical Neurosciences

Not a subscriber?

Subscribe Now / Learn More

PsychiatryOnline subscription options offer access to the DSM-5-TR® library, books, journals, CME, and patient resources. This all-in-one virtual library provides psychiatrists and mental health professionals with key resources for diagnosis, treatment, research, and professional development.

Need more help? PsychiatryOnline Customer Service may be reached by emailing [email protected] or by calling 800-368-5777 (in the U.S.) or 703-907-7322 (outside the U.S.).

Media

Figures

Other

Tables

Share

Share

Share article link

Share